| YGL、YLL、YLW hot carrier heating furnace
of fire coal |
Operation principle :
The organic hot carrier heating
furnace of fire coal is by regarding bituminous coal as fuel,
heat conduction oil in order to heat carriers,utilize and force
liquid of circulation oil pumps by circulations, special industry
stove of direct current type returned to heat again after sending
and give and use hot equipment heat energy. |
| |
|
| Vertical fire coal stove |
Vertical regular stove arranged
fire coal stove |
| |
| Horizontal fire coal
stove |
|
| Brief introduction of the products: |
1、Can get relatively high job temperature under the relatively
low function pressure .
2、Can carry on steady heating and temperature control .
3、Under the load of each grade, thermal efficiency can keep
the best level.
4、Liquid phase send heat energy hot carrier the saturation steam
pressure less than 70 timeses of water relativelies at 300℃,
heat 50% of energy-conservation more than the steam.
5、There is complete function that controls and measure the device
safely.
6、conomize on electricity, economize on fuel, economize on water
, one consume , each regain and make the investment month. |
| |
| YGL、YLL、YLW hot carrier heating furnace
of fire coal: |
| Technical
specification |
Parameter |
Specification
MW |
YGL |
YLL(Vertical) |
YLW(Horizontal) |
| 0.2 |
0.35 |
0.5 |
0.7 |
0.7 |
0.93 |
1.17 |
1.4 |
1.6 |
1.9 |
2.3 |
2.9 |
3.5 |
4.2 |
4.7 |
5.8 |
| Amount supports heat
|
15 |
30 |
40 |
60 |
60 |
80 |
100 |
120 |
140 |
160 |
200 |
250 |
300 |
360 |
400 |
500 |
| Burnning way |
Regular arranged
stove |
Roller chain arranged
stove |
Roller chain arranged
stove |
| Produce oil temperature
|
300 |
300 |
300 |
| Design pressure MPA |
0.6 |
1.0 |
1.0 |
| Suitable fuel |
Similar bituminous
coal |
Similar bituminous
coal |
Similar bituminous
coal |
| Nominal diameter
DN |
50 |
100 |
100 |
100 |
100 |
100 |
100 |
125 |
125 |
150 |
150 |
150 |
200 |
200 |
200 |
200 |
| Systematic installed
capacity
KW |
10.7 |
18.7 |
22.7 |
25 |
23.8 |
48.7 |
48.7 |
48.7 |
50 |
72.3 |
83.2 |
83.2 |
115 |
115 |
115 |
160 |
| Size
of appearance |
Length
m |
1.3 |
1.7 |
1.7 |
2.0 |
4.8 |
4.8 |
4.8 |
5.3 |
5.0 |
5.0 |
6.0 |
7.0 |
7.0 |
7.0 |
7.8 |
7.8 |
| Width
m |
1.3 |
1.7 |
1.7 |
2.0 |
2.2 |
2.2 |
2.4 |
2.3 |
2.2 |
2.3 |
2.4 |
2.5 |
2.6 |
2.6 |
2.6 |
3.2 |
| Height
m |
2.8 |
3.5 |
3.9 |
3.95 |
4.8 |
5.3 |
5.5 |
5.9 |
3.5 |
3.5 |
4.9 |
4.9 |
5.3 |
5.3 |
5.3 |
5.3 |
| Greatest
transport weight
t |
1.9 |
2.3 |
2.4 |
3.0 |
16.2 |
17.2 |
18.0 |
23.7 |
14.4 |
16.4 |
18.6 |
20.8 |
26.9 |
32.3 |
32.3 |
37.1 |
|
| ※The above data is only for reference, that publish the factory
drawing serves as the standard. |
| |
| Supply
range of hot carrier stove of fire coal(Form a complete set
and complement the machine according to different types): |
| Body package of the stove |
Hot coal note oil pump |
Air preheater |
Inflation trough |
Oil filter |
Coaling machine |
Spare part |
| Burnning device |
Air-blower |
Dust remover |
Oil storage trough |
Dreg machine |
Instrument, valve |
Technical data |
| Hot coal circulation pump |
Air-introduced machine |
Electric switch board |
Oil gas separator |
Adjust speed case |
Flue |
|
|
| ※It is only for reference that the above supplies the range,