| YYL(W) fuel, gas hot carrier boiler
|
Operation principle:
The organic hot carrier heating
furnace of fire coal is by regarding bituminous coal as fuel,
heat conduction oil in order to heat carriers,utilize and force
liquid of circulation oil pumps by circulations, special industry
stove of direct current type returned to heat again after sending
and give and use hot equipment heat energy. |
| |
| Brief introduction of the products: |
| 1、Can get relatively high job temperature under the relatively
low function pressure .
2、Can carry on steady heating and temperature control .
3、Under the load of each grade, thermal efficiency can keep
the best level.
4、Liquid phase send heat energy hot carrier the saturation
steam pressure less than 70 timeses of water relativelies
at 300℃, heat 50% of energy-conservation more than the steam.
5、There is complete function that controls and measure the
device safely.
6、conomize on electricity, economize on fuel, economize on
water , one consume , each regain and make the investment
month.
7、The sanitation and hygiene of boiler room , accord with
the individualized request even more. |
| |
|
| Vertical fire coal stove |
Horizontal fire coal stove |
|
| YYL Vertical、YYW Horizontal fire coal
stove : |
| Technical
specification\Parameter
\Specification
(MW) |
0.2 |
0.35 |
0.5 |
0.7 |
0.9 |
1.2 |
1.4 |
1.5 |
1.8 |
2.3 |
2.9 |
| Amount supports heat
|
15 |
30 |
40 |
60 |
80 |
100 |
120 |
125 |
150 |
200 |
250 |
| Produce oil temperature |
300 |
| Design pressure
MPA |
0.6 |
1.0 |
| Suitable fuel |
Light oil, heavy oil,
natural gas, coal gas |
| Nominal diameter DN |
50 |
100 |
100 |
100 |
100 |
125 |
125 |
125 |
150 |
150 |
150 |
| Systematic installed
capacity KW |
8.5 |
14 |
18.6 |
22.1 |
26.8 |
34.8 |
34.8 |
34.8 |
45 |
70 |
70 |
| Vertical |
Size
of appea
rance |
Length m |
1.3 |
1.6 |
1.7 |
2.0 |
2.0 |
2.2 |
2.3 |
2.4 |
2.5 |
2.7 |
|
| Width
M |
1.2 |
1.5 |
1.6 |
1.8 |
1.9 |
1.9 |
2.0 |
2.0 |
2.3 |
2.3 |
|
| Height M |
3.0 |
4.0 |
4.2 |
5.0 |
5.4 |
5.4 |
5.6 |
6.2 |
6.3 |
7.6 |
|
| Greatest
transport
weight T |
1900 |
2800 |
3500 |
4400 |
6200 |
6200 |
7500 |
8400 |
10300 |
12500 |
|
| Horiz
ontal |
Size
of appear
ance |
Length
m |
2.2 |
3.0 |
3.1 |
3.5 |
3.8 |
3.8 |
4.5 |
|
4.9 |
5.9 |
6.2 |
| Width
M |
0.9 |
1.0 |
1.1 |
1.3 |
1.5 |
2.0 |
2.2 |
|
2.4 |
2.4 |
2.6 |
| Height M |
1.2 |
1.4 |
1.6 |
1.8 |
2.0 |
2.2 |
2.4 |
|
2.5 |
2.5 |
2.9 |
| Greatest transport
weight T |
3100 |
3700 |
4000 |
4300 |
6200 |
6200 |
6600 |
|
7000 |
9300 |
11500 |
|
| ※The above data is only for reference, that publish the factory
drawing serves as the standard. |
| |
| Supply
range of hot carrier stove of fire coal(Form a complete set
and complement the machine according to different types): |
| Body package of the stove |
Hot coal note oil pump |
Oil storage trough |
Oil gas separator |
Fuel filter |
| Burnning |
Fuel oil sends the pump |
Fuel oil stores the trough |
Instrument, valve |
Spare part |
| Hot matchmaker's circulation pump
|
Fuel oil sends the pump |
Oil filter |
Switch board of electric apparatus
|
Technical data |
|
| ※It is only for reference that the above supplies the range,